You are about to change tabs!!!

Menu items here are different on each tab

Only menu items relevant to installers will be shown when in the installers tab.


Do not show again

Net2 RS485 dataline modules Print


RS485 protection module protects against lightning
Buy direct from Paxton Access
About - The RS485 protection module (325-050) has been designed to protect the Net2 control units connected to the RS485 data line from being damaged under severe electrical storm conditions. The module helps reduce the passage of high voltage along the dataline.

The RS485 IDC connection module (325-040) will speed up the installation of a Net2 control unit with a CAT5 dataline. Many installations are wired in CAT5 and this module converts a standard screw terminal Net2 Network connection into Krone terminal stripes designed for this cable type.


Installation - RS485 protection module: The device should be placed at either end of any vulnerable cabling to isolate the section. The two connector strips on the device have positions for each individual wire. A Krone insertion tool (not supplied) should be used to ensure a good connection of the wires into the terminal strip.

RS485 IDC connection module: The two connector strips on the device have positions for each individual wire. Once wired in accordance with the instructions, pull off the screw terminal block for the Net2 ACU\'s network port and replace it with this module.





Sales code Description Retail price*
325-050 RS485 protection module, pack of 2 €29.48
325-040 RS485 IDC connection module, pack of 5 €37.52

* Retail prices are subject to VAT and do not include the cost of installation